Dental Low Speed Handpiece Dental Buy 10 Get 11 Ceramic Bearing

Product Details
Customization: Available
Condition: New
Certification: ISO13485
Still deciding? Get samples of US$ 18/Piece
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

In-stock Capacity
The supplier has In-stock capacity
Quality Assurance
The supplier provides quality assurance
R&D Capabilities
The supplier has 1 R&D engineers, you can check the Audit Report for more information
Management Certification
The supplier has quality management system certification, including:
ISO13485:2016
to see all verified strength labels (25)
  • Dental Low Speed Handpiece Dental Buy 10 Get 11 Ceramic Bearing
  • Dental Low Speed Handpiece Dental Buy 10 Get 11 Ceramic Bearing
  • Dental Low Speed Handpiece Dental Buy 10 Get 11 Ceramic Bearing
  • Dental Low Speed Handpiece Dental Buy 10 Get 11 Ceramic Bearing
  • Dental Low Speed Handpiece Dental Buy 10 Get 11 Ceramic Bearing
  • Dental Low Speed Handpiece Dental Buy 10 Get 11 Ceramic Bearing
Find Similar Products
  • Overview
  • Product Description
Overview

Basic Info.

Model NO.
MY-1003S
Light Way
Without Light
Water Way
Inner Channel
Usage Times
Non-Disposable
Application
Adult, Child
Loading Way
Gland Type
Head Diameter
Middle Head
Exhaust Way
Internal Exhaust
Number of Holes
E-Type
Connection
2 Hole/4 Hole
Rotating Speed
Low-Speed Handpiece
Grade
A Grade
Air Pressure
0.20-0.3MPa
Water)
0.2(MPa)-0.23(MPa
Bearing
Ceramic Bearing
Max Speed
25, 000rpm/Min
Warranty
One Year, Cartridge Half Year
Place of Origin
Guangdong, China
Connector
2 Hole/4 Hole
Delivery Detail
Within 3~5 Days After Payment
Noise
≤65dB
Transport Package
Caton Box
Specification
CE
Trademark
M&Y OEM
Origin
China
Production Capacity
5000 Set/Sets Per Month

Product Description

Product Description

Dental low speed  handpiece Dental Buy 10 Get 11 Ceramic Bearing 

 
Product name 
WH low speed kits Noise ≤65dB
Bearing Ceramic bearing Air pressure 0.20-0.3MPa
Material Stainless steel Water 0.2(Mpa)-0.23(Mpa)
Water way Inner waterway Color Blue ring
Connector 2 hole/4 hole Max speed 25,000rpm/min
 
- Low Speed 22,000-27,000 rpm.

The shank of the instrument mounted therein is 2.35 mm

- Fastening of the instruments with a turning latch

- Autoclavable 135°

- For any lab or E-type motors

Contra angle: driven by a motor, it is used to rotate the drill bit and polishing head. Bending machines allow insertion of
various rotating instruments.

Air Motor: The motor is the power source that drives the dental handpiece to rotate at a low speed.

 
Straight handpiece:Can be sterilized by high temperature,Connect with air motor.

1. When using the dental handpiece, it must be lubricated strictly according to the instruction manual. Generally, the high-speed dental handpiece is lubricated twice a day. Low speed handpieces (straight, curved, motor) once a day.

2. The working air pressure of the dental handpiece must be strictly in accordance with the instructions. In general, the working air pressure of two-hole and three-hole dental handpieces is 2-2.2Kg, and the working air pressure of four-hole, five-hole, and six-hole dental handpieces is 2.4-2.5Kg (referring to the pressure at the interface between the dental handpiece and the connecting pipe). The pressure must be adjusted when the new treatment machine is used, and the pressure of the treatment machine must be re-calibrated after a period of use (about one month).

3. Disinfection: high-temperature steam should be used for disinfection, chemical liquid and dry heat should not be used for disinfection. The disinfection temperature is 135°C, and the maximum time should not exceed 30 minutes. It must be cleaned before disinfection and must be lubricated after disinfection. Note: For dental handpieces with quick-change joints, the dental handpieces should be removed, and only the dental handpieces should be disinfected, not the joints. For low-speed dental handpieces, please remove the straight and curved handpieces for disinfection. Use alcohol to clean the dental handpiece when it is dirty.

4. Do not use standard, rusty or aging burs or grinding heads.

5. Gland The high-speed dental handpiece must not press the gland when it is rotating, so as not to damage the movement. Straight and bending machines cannot load and remove burs when they are rotating.

6. The bur, grinding head or "standard rod" should be removed and installed once a day, so as to avoid rusting of the bur if it is not removed for a long time.
Dental Low Speed Handpiece Dental Buy 10 Get 11 Ceramic Bearing

Company Introduction:
-We have obtained ISO13485 and CE standards certification.
-We are one of the professional dental handpiece manufacturer in China.
-We are able to customize tools according to your requirements.
-We have a professional team and more than 80 sets of processing equipment.
-12-year-old manufacturer,Factory Direct.
-We Provide You High Quality Dental Handpiece with Low MOQ and Competitive Price.
-We Manufacture Top Quality Dental Equipment You Can Trust.

Sourcing Service:
-If you can not find dental products on our website, you can contact us. We will offer a sourcing service for you and give you a quotation within 24
hours.
-OEM/ODM

Contact me for quote now:
mydental.en.made-in-china.com
 
 
Dental Low Speed Handpiece Dental Buy 10 Get 11 Ceramic BearingDental Low Speed Handpiece Dental Buy 10 Get 11 Ceramic BearingDental Low Speed Handpiece Dental Buy 10 Get 11 Ceramic BearingDental Low Speed Handpiece Dental Buy 10 Get 11 Ceramic BearingDental Low Speed Handpiece Dental Buy 10 Get 11 Ceramic BearingDental Low Speed Handpiece Dental Buy 10 Get 11 Ceramic BearingDental Low Speed Handpiece Dental Buy 10 Get 11 Ceramic Bearing

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier