• Dental 1: 1 Contra Angle Standard Head Push Button with Internal Water Spray Handle X25 Air Turbine Dentist Instrument Tools
  • Dental 1: 1 Contra Angle Standard Head Push Button with Internal Water Spray Handle X25 Air Turbine Dentist Instrument Tools
  • Dental 1: 1 Contra Angle Standard Head Push Button with Internal Water Spray Handle X25 Air Turbine Dentist Instrument Tools
  • Dental 1: 1 Contra Angle Standard Head Push Button with Internal Water Spray Handle X25 Air Turbine Dentist Instrument Tools
  • Dental 1: 1 Contra Angle Standard Head Push Button with Internal Water Spray Handle X25 Air Turbine Dentist Instrument Tools
  • Dental 1: 1 Contra Angle Standard Head Push Button with Internal Water Spray Handle X25 Air Turbine Dentist Instrument Tools

Dental 1: 1 Contra Angle Standard Head Push Button with Internal Water Spray Handle X25 Air Turbine Dentist Instrument Tools

Condition: New
Certification: ISO13485
Material: Stainless Steel
Light Way: Without Light
Water Way: Inner Channel
Usage Times: Non-Disposable
Samples:
US$ 45/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2015

Suppliers with verified business licenses

Guangdong, China
In-stock Capacity
The supplier has In-stock capacity
Quality Assurance
The supplier provides quality assurance
R&D Capabilities
The supplier has 1 R&D engineers, you can check the Audit Report for more information
Management Certification
The supplier has quality management system certification, including:
ISO13485:2016
to see all verified strength labels (25)
  • Overview
  • Product Parameters
Overview

Basic Info.

Model NO.
MY-X25
Application
Adult, Child
Loading Way
Gland Type
Head Diameter
Middle Head
Exhaust Way
Internal Exhaust
Number of Holes
E-Type
Connection
E-Type
Rotating Speed
1:1
Ratio
1:1
Bur Type
1.59-1.60mm
Max Speed
400000min/Rpm
Noise
Less Than 60dB
Chuck Type
Push Button
Bearing
Caramic Bearing
Packaging
Plastic Box CTN Box
Delivery Detail
Within 3~5 Days After Payment
Transport Package
Plastic Box, CTN, Box
Specification
CE
Trademark
M&Y OEM
Origin
China
HS Code
9401809000
Production Capacity
1000 PCS/Month

Product Description

Product Parameters

Dental 1:1 Contra Angle Standard Head Push Button with Internal Water Spray Handle X25 Air Turbine Dentist Instrument Tools

Products name 1:1 contra angle  Max speed 400000min/rpm
Ratio 1:1 Light Without fiber optical
Bearing Caramic bearing Materials Stainless steel
Connector E type Chuck type Push button
 
Packing list
1PC/Box Handpiece
 
 
X25 Without Fiber Optic
Dental 1: 1 Contra Angle Standard Head Push Button with Internal Water Spray Handle X25 Air Turbine Dentist Instrument ToolsDental 1: 1 Contra Angle Standard Head Push Button with Internal Water Spray Handle X25 Air Turbine Dentist Instrument ToolsDental 1: 1 Contra Angle Standard Head Push Button with Internal Water Spray Handle X25 Air Turbine Dentist Instrument ToolsDental 1: 1 Contra Angle Standard Head Push Button with Internal Water Spray Handle X25 Air Turbine Dentist Instrument ToolsDental 1: 1 Contra Angle Standard Head Push Button with Internal Water Spray Handle X25 Air Turbine Dentist Instrument ToolsDental 1: 1 Contra Angle Standard Head Push Button with Internal Water Spray Handle X25 Air Turbine Dentist Instrument ToolsDental 1: 1 Contra Angle Standard Head Push Button with Internal Water Spray Handle X25 Air Turbine Dentist Instrument ToolsDental 1: 1 Contra Angle Standard Head Push Button with Internal Water Spray Handle X25 Air Turbine Dentist Instrument Tools
Dental handpieces right use way:
1. The need to use a clean , dry , oil-free air compressors for medical use ;
2. The air pressure between 2.3-2.8kgf / cm2;
3. Place the adapter with quick connector at the bottom of a combination of dental handpieces , and confirm that the card lock fixed ;
4. Press the pedal , handpiece operation and examine whether the normal operation of the spray head . If everything is normal, you can start using the handpiece.

After each patient use , maintenance should be done as follows
1. First remove the diamond burs , and clean up all the teeth on dental handpieces precipitate ;
2. Use a metal needle to clean the spray holes and fumaroles ;
Note: The spray holes and diamond burs into 40 -degree angle , fumaroles and diamond burs to a 30 degree angle.
3. Place the clean lubricating oil is sprayed into the axial hole 1-2 seconds ( diamond burs is plugged holes ) ;
4. In the bottom of the handpiece were ( with / without quick connector ) two kinds of styling , make the right amount of lubricant is injected into the bottom ;
5. The handpiece with quick connector combination ( first determine the water switch is turned off )
6. Replace the diamond burs , surrounded by white silk cloth handpiece head ( make sure the needle does not touch the diamond burs and white gauze , so as not to tie ) ;
7. pedal depressed for about 20 seconds , look at whether there is in white gauze on any stain. If there are stains on the white gauze , again, add oil , starting from item 4 continued routine maintenance , know that white gauze until no stain ;
8. Finally, no more than 135 degrees Celsius temperature and high pressure sterilization.

Handpiece routine maintenance
Fault: the occurrence of undesirable phenomena water
( 1 ) inadequate water supply .
( 2 ) the amount of water is not uniform.
( 3 ) is not a mist of water .
( 4 ) no water completely .

Solution: Check the water blocked the site
( 1 ) pipeline : the turbines removed to check for the amount of water flowing from the pipeline . If there is no water out, it may be pipes or water treatment units system problems ( bad or wrong operation , there is not enough water pressure ) .
( 2 ) interface : the interface conductors commissioning . Without the right amount of water flowing out , it indicates a problem at the interface ( such as clogged scale water supply systems or interface loose , resulting in insufficient pressure ) .
( 3) The body of the phone : the shaft from the turbine to remove , install interface running on . If there is no outflow amount of water, it is the problem turbines within the body ( water holes or dirt clogging turbines within the water supply system clogging ) .
( 4 ) shaft : If the above three normal outflow of water , it is the axis of the core problem (water nozzle clogging ) .

Axis core spray nozzle clogging .
Solution:

( 1 ) remove the end cap , remove the spool core .
( 2 ) the brush behind the nozzle cleaning needle is removed , insert the needle straight spout .
( 3 ) nozzle cleaning needle to be inserted into the upper section of the trench ( bur through jet slot ) at the till . Part of this special brush with dust brush clean.
( 4 ) the use of three guns and other bur blowing from the side .
(5 ) mounted on the shaft head , be sure to properly install the 0 -ring .

Bur easy to fall off , bur not pull it out , the axis vibration.
Solution:

(1 ) Select the bur , bur must confirm the allowable speed range specified by the manufacturer , or else when the cutting load is greater than the chuck clamping force bur easily.
( 2 ) mini- head bur should use a short handle , easy to fall off when attached to the shank burs .
( 3 ) Do not use worn tapered bur , curved bur bur missing edge , otherwise it will affect the durability of the bearing Must be drawn .
(4 ) installation bur bur confirm indeed firmly installed , if not into the depths of shallow plug can cause dangerous bur flying.

Company Introduction:
-We have obtained ISO13485 and CE standards certification.
-We are one of the professional dental handpiece manufacturer in China.
-We are able to customize tools according to your requirements.
-We have a professional team and more than 80 sets of processing equipment.
-12-year-old manufacturer,Factory Direct.
-We Provide You High Quality Dental Handpiece with Low MOQ and Competitive Price.
-We Manufacture Top Quality Dental Equipment You Can Trust.

Sourcing Service:
-If you can not find dental products on our website, you can contact us. We will offer a sourcing service for you and give you a quotation within 24
hours.
-OEM/ODM

Contact me for quote now:
mydental.en.made-in-china.com
 
 
Dental 1: 1 Contra Angle Standard Head Push Button with Internal Water Spray Handle X25 Air Turbine Dentist Instrument ToolsDental 1: 1 Contra Angle Standard Head Push Button with Internal Water Spray Handle X25 Air Turbine Dentist Instrument ToolsDental 1: 1 Contra Angle Standard Head Push Button with Internal Water Spray Handle X25 Air Turbine Dentist Instrument ToolsDental 1: 1 Contra Angle Standard Head Push Button with Internal Water Spray Handle X25 Air Turbine Dentist Instrument ToolsDental 1: 1 Contra Angle Standard Head Push Button with Internal Water Spray Handle X25 Air Turbine Dentist Instrument Tools

 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now